To load control processor software:
1. Connect a computer to the Maintenance Port of the HSD transceiver.
2. Turn on the computer.
3. Save the HSD Load Program file (PN 1110-SW-1021) to a folder on your PC.
(Recommended: Create a folder named HSD Load in the PC’s root directory and
save the load application file to this folder.)
4. Apply power to the HSD or HSD-X transceiver.
5. Close all other applications running on the computer (especially programs that
use the serial COM port, e.g. HyperTerminal). The load program may not execute
successfully if other programs are running.
6. In the HSD Load folder, double-click on the ADT_LOAD.exe file to launch the load
application.
The ADT_LOAD application opens in a DOS window and displays the “Load
Target” menu, as displayed in the example below.
The ADT_LOAD application prompts the user to select a “Target.”
7. From the “Which Target” menu:
To load control processor software (for example, adt70.bin) to the control
processor, press
0
8. Press Enter.
The load application prompts you to type in a filename.
9. Type the appropriate filename for the software being loaded to the HSD Control
Processor (for example adt70.bin), and then press
Enter.
The application prompts you to select the COM port that is connected to the HSD
or HSD-X.
HSD/HST LOADER Vx.x -- Mon Mar 24 12:12:17 2003
which target ?
0 = control processor
1 = channel card #1
2 = channel card #2
3 = HPA application
4 = data i/o card
5 = HPA application with manual setup
6 = HPA application plus boot with manual setup
7 = HPA application plus boot
8 = channel card #1 boot code
9 = channel card #2 boot code
11 = channel card #1 pic code
12 = channel card #2 pic code
13 = HCM application
14 = HST ORT
15 = HSD ORT
16 = HSD-X ORT
?