User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 4–97
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Call failure Unit is strapped to an
incorrect system mode of
installation
In menu 3, select
Item
L (List
EEPROM)
• Verify the system mode
strapping is correct.
• Reset the system and
observe the initialization
display; it shows the HSD
unit’s powering up,
self-test results. The
Initialization display lists
the installation mode
configuration for the unit.
• If the mode displayed is not
strapped or is incorrectly
strapped, a temporary
setting may be used—in
Menu 3, select M (misc.
EEPROM parameters),
then select parameter 16
(Channel Card Category)
and configure the HSD to
the correct mode (e.g. ‘0’
for SAT-906 ,‘1’ for
Stand-Alone…). Reset the
unit and try the call again.
Call failure Dialing sequence was
incomplete or incorrect
Activate report 21
and 23
Figure 4–48 – No
call
• Verify the number you are
calling and try the number
again.
• Refer to the HSD User’s
Guide for detailed
operating instructions.
• Ensure that you end the
dialing sequence by
pressing # (pound key)—
pressing # at the end of the
dialing string signals the
system to “send” the call.
Log-on
request fails
Unit is not transmitting Activate
maintenance
reports 21 and 23
(See Figure 4–53)
• Check for a defective or
loose cable.
• Check for HPA fault.
• Ensure the HSD is secured
properly to the ARINC
connector in the tray.
Table 4–27. Troubleshooting and Fault Isolation
Fault Description
Maintenance
Report
Check