Call failure Unit is strapped to an
incorrect system mode of
installation
In menu 3, select
Item
L (List
EEPROM)
Verify the system mode
strapping is correct.
Reset the system and
observe the initialization
display; it shows the HSD
unit’s powering up,
self-test results. The
Initialization display lists
the installation mode
configuration for the unit.
If the mode displayed is not
strapped or is incorrectly
strapped, a temporary
setting may be used—in
Menu 3, select M (misc.
EEPROM parameters),
then select parameter 16
(Channel Card Category)
and configure the HSD to
the correct mode (e.g. ‘0’
for SAT-906 ,‘1’ for
Stand-Alone…). Reset the
unit and try the call again.
Call failure Dialing sequence was
incomplete or incorrect
Activate report 21
and 23
Figure 4–48 – No
call
Verify the number you are
calling and try the number
again.
Refer to the HSD User’s
Guide for detailed
operating instructions.
Ensure that you end the
dialing sequence by
pressing # (pound key)—
pressing # at the end of the
dialing string signals the
system to “send” the call.
Log-on
request fails
Unit is not transmitting Activate
maintenance
reports 21 and 23
(See Figure 4–53)
Check for a defective or
loose cable.
Check for HPA fault.
Ensure the HSD is secured
properly to the ARINC
connector in the tray.
Table 4–27. Troubleshooting and Fault Isolation
Fault Description
Maintenance
Report
Check