User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 1–14
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
3. Equipment Description
This section describes the physical and environmental specifications of the equipment.
A. Applicable Documents
• High speed data terminal Setup Guide, EMS SATCOM PN MN-1110-10048
• ARINC 741. ARINC Report 413A – Guidance for Aircraft Electrical Power Utilization
and Transient Protection, Attachment 3-2, Wire Shielding and Grounding
Requirements and Appendix 7
B. Reference Documents
• HSD-64/128 Software Control Document, EMS SATCOM PN LI-1110-10136
• HSD-X Software Control Document, EMS SATCOM PN LI-1110-10181
C. Equipment Specifications
This section provides the equipment specifications for the HSD and HSD-X transceivers.
Table 1–13 lists the physical and equipment specifications for the HSD transceiver. Table
1–14 lists the RTCA/DO-160D environmental characteristics and specifications for the
HSD transceiver.
Table 1–15 lists the physical and equipment specifications for the HSD-X transceiver.
Table 1–16 lists the RTCA/DO-160D environmental characteristics and specifications for
the HSD-X transceiver.
Table 1–13. HSD Equipment Characteristics and Specifications
CHARACTERISTIC SPECIFICATION
Certification/related documents
ARINC characteristics 600-12, Air Transport Avionics Equipment
Interfaces, December 12, 1998
Appendix 10 of the ARINC 704-7
RTCA documents RTCA/DO-160D, Environmental Conditions and
Test Procedures for Airborne Equipment, July 29,
1997
HSD Software RTCA/DO-178B Level E
Physical Size
Height 19.93 cm (7.85 in)
Width 25.91 cm (10.20 in)
Length 36.45 cm (14.58 in)
Weight 13 Kg (28.7 lbs)
Mounting information 8 MCU Tray (per ARINC 600, 8 MCU LRU)
Maintenance requirements No scheduled maintenance is required
Electrical specifications