User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 1–17
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
Voltage spike 115 V ac units: Category A
28 V dc units: Category A
Audio frequency susceptibility 115 V ac units: Category A
28 V dc units: not tested
Induced signal susceptibility 115 V ac units: Category Z
28 V dc units: not tested
RF susceptibility 115 V ac units: Category RR
28 V dc units: not tested
Emission of RF Energy 115 V ac units: Category B
28 V dc units: Category B
Lightning Direct Effects Category X (not applicable)
Icing Category X (not applicable)
Table 1–15. HSD-X Transceiver Specifications
CHARACTERISTIC SPECIFICATION
Certification/related documents
ARINC characteristics 600-12, Air Transport Avionics Equipment
Interfaces, December 12, 1998
Appendix 10 of the ARINC 704-7
RTCA documents RTCA/DO-160D, Environmental Conditions
and Test Procedures for Airborne Equipment,
July 29, 1997
HSD-X Software RTCA/DO-178B Level E
Physical
Size 2 MCU ARINC 600-10 Form Factor
Weight 8.8 lbs maximum
Cooling air Unit capable of continuous duty cycle operation,
with or without forced air-cooling provided, as
per ARINC 600 specifications. Refer to
1110-E-0401. (See "Installation" on page 3-1.)
Mounting Information As per ARINC 600 specifications. Refer to
1110-E-0401. (See "Installation" on page 3-1.)
Maintenance Requirements No maintenance requirements
Electrical
Power Dissipation 34 Watts
Input Power 115 V ac, 400 Hz, 75 va
Input frequency range 1530.0 to 1559.0 MHz
Output frequency range 1626.5 to 1660.5 MHz
Receiver input impedance 50 ohms
Table 1–14. HSD RTCA/DO-160D Environmental Characteristics
CHARACTERISTIC SPECIFICATION