SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
23-15-30 3-5
8 MAY 09
F. HSD-Xi Input/Output Strapping
Table 3-1 provides the Input/Output (I/O) strapping for the HSD-Xi.
Table 3-1 HSD-Xi Input/Output Strapping
MP11A MP11B MP11C Input/Output Configuration
1 1 1 Invalid
1 1 0 Restricted (disable Data I/O)
1 0 1 MPDS (Future)1
1 0 0 SCPC (M4) only
0 1 1 Unrestricted (recommended if
th
ere are no specific user
requirements)
0 1 0 Not Assigned
0 0 1 Not Assigned
0 0 0 Reserved
NOTE: MP11D: Reserved, 0 = FWD Address Comm
G. User Interfaces
For the HSD-Xi terminal Ethernet interface, in
stall an RJ-45 interface connector in the
cabin area. For the ISDN interface, install an RJ-45 interface connector in the cabin area.
5. Installing the HSD-Xi and ESCM
Install the HSD-Xi and ESCM according to the System Interconnection diagrams,
Figure 3-7, Figure 3-8, Figure 3-9, and Figure 3-10.
Figure 3-4, Figure 3-5, and Figure 3-6 provide outline drawings for the HSD-Xi
terminal
and ESCM. Mount the ESCM on a flat surface using
four screws or bolts that fit the 0.125
inch holes in the mounting flange. You can install the ESCM a maximum of three meters
away from the HSD-Xi terminal.
A. Hardware and Software Requirements
You need a HSD-Xi terminal, 1252-A-4100, an
d an ESCM, 1252-A-4120, to use SBB
services.
You need the following software to use SBB
services.
HSD-Xi, LI-1252-42001
HSD-440, LI-1252-33374
B. User Interfaces
You can access SBB services through the
following interfaces:
Ethernet
•ISDN