User Manual Part 1

Page 1-2
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
B. JetWave™ System LRU Leading Particulars
(1) Refer to Table 1-2 for the Modman leading particulars.
(2) Refer to Table 1-3 for the APM leading particulars.
(3) Refer to Table 1-4 for the KANDU leading particulars.
(4) Refer to Table 1-5 for the KRFU leading particulars.
(5) Refer to Table 1-6 for the TMA leading particulars.
(6) Refer to Table 1-7 for the FMA leading particulars.
(7) Refer to Table 1-8 for the B757 FMA radome perticulars.
.
APM 90401121
KANDU 90401566
KRFU CC1 90401203
KRFU CC2 90402346
KRFU 90401202
FMA 90000380-1
TMA 904000013-0001
A791 FM radome 90400017
Non-A791 FM radome 90400016
Table 1-2. Modman Leading Particulars
Characteristic Specification
Length 14.41 inches (366.0 mm) maximum
Width 5.02 inches (127.5 mm) maximum
Height 7.88 inches (200.2 mm) maximum
Weight 14.00 pounds (6.4 kg) maximum
Operating voltage 115 VAC, 400 Hz
Power consumption 60 watts maximum
NOTE: Honeywell recommends that wiring and cooling is
designed for 100 watts in order to allow for seamless upgrades
to the Modman with enhanced capability at a later date.
Power dissipation 59 watts maximum
Table 1-1. JetWave™ System LRUs (Cont)
LRU PN