User Manual Part 1

Page 1-3
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Cooling 48.5 lb/hr (22 kg/hr) at 104°F (40°C)
Operating temperature 5°F (-15°C) to 131°F (55°C)
Mounting information 4-MCU, forced-air, ARINC 600 series tray
Maintenance No scheduled maintenance required
Interfaces J1A - PODD, PIESD, and AISD
J1B - APM, Aircraft, APM, PODD, PIESD, AISD, and KANDU
J1C - IF to/from KRFU and aircraft power
Table 1-3. APM Leading Particulars
Characteristic Specification
Length 4.50 inches (101.6 mm) without connector
Width 4.00 inches (79.8 mm) maximum
Height 1.3 inches (33 mm) maximum
Weight 12 ounces (0.34 kg) maximum
Operating voltage 5 VDC, 300 mA maximum, from the Modman
Power consumption 0.3 watts maximum
Power dissipation 0.3 watts maximum
Cooling No forced-air cooling required
Operating temperature 5°F (-15°C) to 131°F (55°C)
Maintenance No scheduled maintenance required
Interface J1 - Modman
Table 1-4. KANDU Leading Particulars
Characteristic Specification
Length 11.02 inches (28 cm) maximum
Width 9.075 inches (23.05 cm) maximum
Height 4.76 inches (12.1 cm) maximum
Weight 8.8 pounds (4.0 kg) maximum
Operating voltage 115 VAC, 400 Hz
Power consumption 200 watts Class A maximum average power
115 watts Class B maximum average power
Table 1-2. Modman Leading Particulars (Cont)
Characteristic Specification