User Manual Part 1

Page 1-5
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Length 16.55 inches (42.0 cm) maximum
Width 9.01 inches (22.9 cm) maximum
Height 2.08 inches (7.1 cm) maximum
Weight 11.30 pounds (5.1 kg) maximum
Operating voltage 115 VAC, 400 Hz
Power consumption 150 watts at maximum output power
Power dissipation 132 watts at maximum output power
Cooling Conductive-cooled through the baseplate with thermal pad
Operating temperature -67°F (-55°C) to 158°F (70°C)
Maintenance No scheduled maintenance required
Interfaces J1 - Aircraft power input
J2 - Control interface from KANDU
J3 - RF TX to OAE
J4 - RF RX from OAE
J5 - IF TX from Modman
J6 - IF RX to Modman
Forced air configuration:
Length 18.05 inches (45.8 cm) maximum
Width 9.01 inches (22.9 cm) maximum
Height 3.23 inches (8.4 cm) maximum
Weight 14.6 pounds (6.6 kg) maximum
Operating voltage 115 VAC, 400 Hz
Power consumption 150 watts at maximum output power
Power dissipation 132 watts at maximum output power
Cooling Forced air, 169.8 lb/hr (77 kg/hr) at 104°F (40°C) at sea level
Operating temperature -67°F (-55°C) to 158°F (70°C)
Maintenance No scheduled maintenance required
Table 1-5. KRFU Leading Particulars(Cont)
Characteristic Specification