SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Figure 2-10. Typical Ground Strap Arrangement for A791 Compliant Fittings
The aircraft coordinate system orientation and fitting layout are shown in Figure 2-11.
Figure 2-11. Aircraft Coordinate System Orientation and Fit
ting Layout
(a) Position and install the A791 based AIM fittings onto aircraft fittings for fittings #1, #2,
#5, #6, and #
7.
(b) Use the alignment tools to make sure that th
e fitting slip in X-direction is centered for
fittings #2, #6, and #7.
(c) Make sure that all the fittings are oriented vertically with the alignm
ent tools to help when
you lower the A791 based AIM onto aircraft fittings and the installed fittings pass through
openings in A791 based AIM.
(d) Put the A791 based AIM assembly onto aircraft with an aircraft servicing hoist. Attac
h
the hoist to the A791 based AIM adapter plate at three locations labeled “Hoist Point”.
Make sure that the previously installed fittings on aircraft are still oriented vertically so