SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
When installing the JetWave™ system, follow the cabling requirements listed below:
Ethernet LAN/WAN cables must meet flammability and TIA/EIA568-A CAT 5E requirements.
Carlisle IT (ECS) 422404 or NF24Q100-01 is recommended for Quadrax connections.
Twisted shielded pairs must meet ARINC 791 wiring requirements or equivalent.
Refer to Figure 2-33, Figure 2-34, Figure 2-35, and Figure 2-36 for wire size recommendations.
7. Drawings and Diagrams
Refer to Figure 2-24 for the Modman outline and installation drawing.
Refer to Figure 2-25 for the APM outline and installation drawing.
Refer to Figure 2-26 for the KANDU outline and installation drawing.
Refer to Figure 2-27 for the KRFU PN 90401203, conduction-cooled 1, outline and installation drawing.
Refer to Figure 2-28 for the KRFU PN 90402346, conduction-cooled 2, outline and installation drawing.
Refer to Figure 2-29 for the KRFU PN 90401202, forced air cooled, outline and installation drawing.
Refer to Figure 2-30 for the TMA outline and installation drawing.
Refer to Figure 2-31 for the FMA outline and installation drawing.
Refer to Figure 2-32 for the Fuselage Mount Radome outline and installation drawing.
Refer to Figure 2-33 for the JetWave™ System - TMA interconnect diagram.
Refer to Figure 2-34 for the JetWave™ System - FMA (baseline) interconnect diagram.
Refer to Figure 2-35 for the JetWave™ System - Boeing Specific FMA (external KRFU) interconnect
diagram.
Refer to Figure 2-36 for the JetWave™ System - A350 Specific FMA interconnect diagram.
Table 2-8. Cabling Requirements
Cable Conductor Type
Single
Point
Multiple
Point
Minimum Conductor
Coverage by Shield
Power Lines Single conductor, stranded NA N/A N/A
Ethernet Data Quadrax, twister pair - Yes 100%
RF Coaxial, waveguide - Yes 100%
A429 Twisted pair, stranded - Yes 95%
RS-422 Twisted pair, shielded - Yes 100%
Discrete Twisted pair, shielded, KANDU
Single conductor, shielded, grounds
Yes 100%