User Manual Part 3

Page 3-54
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
System (00) AES menu access
level (02)
0x 0023 Log clearance AES
usage historical log
- Info events - Recording what happened
in the LRU.
- If it is a warning, It is info only.
Configuration (03) 0x 0000 Tail number missing Use the AES Menu interface at
maintenance level to enter the valid tail
number of the aircraft
0x 0001 Configuration file
missing
- First fit: Data load the configuration data
to the Modman LRU with the 615A data
loading process.
- After operational: Replace the APM
LRU (presume its broke since the APM
should not forget an APM file), do the first
fit operation again.
0x 0002 Inter LRU SW
incompatibility
Verify versions of SW with the GUI or
AES menu tool on all LRUs and replace
with correctly configured set of SW.
0x 0003 Geographical map
missing
NO ACTION – this will be updated when
the system is in operation.
0x 0004 Configuration file in
APM missing
- First fit: Data load the configuration data
to the Modman LRU with the 615A data
loading process.
- After operational: Replace the APM
LRU (presume its broke since the APM
should not forget an APM file), do the first
fit operation again.
AES SFTP (04) 0x 0000 Maintenance - Info events - Recording what happened
in the LRU.
- If it is a warning, It is info only.
0x 0001 Factory
0x 0002 Engineering
SNMP
Engineering (05)
0x 0000 Maintenance
0x 0001 Factory
0x 0002 Engineering
0x 0021 Log clearance AES
operational historical
log
0x 0022 Log clearance AES fault
historical log
0x 0023 Log clearance AES
usage historical log
SNMP ARINC 791
(06)
0x 0000 Maintenance
0x 0001 Factory
0x 0002 Engineering
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action