User Manual Part 3

Page 3-58
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Modman (01) Reset (FC) 0x 0003 Reset Pin Info events - Recording what happened
in the LRU.
0x 0004 SW exception
Software
configuration (FD)
0x 0001 HW SW compatibility Reload compatible software with the
A615A data loading process.
0x 0002 LRU SW compatibility
0x 0003 Configuration
parameter missing
Reload the configuration data with the
A615A data loading process.
0x 0004 Primary image
corruption warning
- Reboot the LRU to load valid primary
image and check if fault goes away.
- If not, then a fresh data load of software
is required to load the fresh image.
0x 0005 No valid image Reload compatible software with the
A615A data loading process.
0x 0006 LRU PRI-SEC image
mismatch
- Reboot the LRU to load valid primary
image and check if fault goes away.
- If not, then a fresh data load of software
is required to load the fresh image.
0x 0007 Data load Unit configuration events:
- Critical, something needs to be done
(reload software).
- Warning, then the event was
unexpected, but will sort itself out.
- Info, recording what happened in the
LRU.
0x 0008 Data loader connect
0x 0009 Data loader disconnect
0x 000A Operating image list
0x 000B Secondary image
corruption warning
A fresh data load of software is required
to load the fresh image.
Software runtime
(FE)
0x 0000 Heartbeat failure Software events:
- Critical, will cause the unit to reset.
-Warning, then the event was
unexpected, but will sort itself out.
-Info, recording what happened in the
LRU.
(For software faults there is no reason to
return box.)
0x 0001 GENERAL module
failure
0x 0020 Missing KANDU
information
0x 0021 File system full
0x 0022
thru
0x 007F
Other SW errors
Temperature (FF) 0x 0001 C/R temperature sensor - If it is a warning, It is info only.
- If it is critical, the LRU will shut down
functionally: The LRU is not correctly
installed or there can be a fault in the box
generating the heat.
0x 0002 PSU temperature
sensor
Table 3-20. L3 Codes (Cont)
L1 L2 L3 Code L3 Description Repair Action