KANDU (06) ASC BITE A429
AUX (13)
0x 0000 ARINC 429 AUX post
unresponsive
Hardware faults and events:
- Replace the KANDU.
0x 0001 ARINC 429 AUX
incorrect data
0x 0002 ARINC 429 AUX post
OK
ASC BITE
Ethernet switch
(14)
0x 0000 Ethernet MDIO
unresponsive
Hardware faults and events:
- Replace the KANDU.
0x 0001 Ethernet MDIO
unexpected data
0x 0002 Ethernet MDIO OK
Operational
information (FA)
0x 0000 Mode Transition Info events - Recording what happened
in the LRU.
0x 0001 Parameter
0x 0002 Event
0x 000A Standard electronic
information
0x 000B Honeywell electronic
information
0x 000C Subassembly
information
IP security (FB) 0x 0000 IP security event Use well defined port and IP Address
Reset (FC) 0x 0001 Watchdog Info events - Recording what happened
in the LRU.
0x 0002 Software command
0x 0004 SW exception
0x 0005 Power cycle or reset pin
Software
configuration (FD)
0x 0001 HW SW Compatibility Reload compatible software with the
A615A data loading process.
0x 0002 LRU SW Compatibility
0x 0003 Configuration
parameter missing
Reload the configuration data with the
A615A data loading process.
0x 0004 Primary image
corruption warning
- Reboot the LRU to load valid primary
image and check if fault goes away.
- If not, then a fresh data load of software
is required to load the fresh image.
0x 0005 No Valid Image Reload software with the A615A data
loading process.