14. SNMP
Refer to APPENDIX B on page B-1 for MIB and SNMP information and instructions.
PODD
Network:
Ethernet PA3
(93)
Modman Input
(01)
0x 0000 Ethernet no layer 1 Indicates nothing is connected:
- Check wiring between boxes.
- Check TX box is operating.
- Check RX box is operating.
0x 0001 Ethernet no traffic Is a warning that on traffic has been seen
on the bus, but layer 1 is established so a
physical link exists.
0x 0002 Ethernet high packet
loss
There is an intermittent wiring problem or
hardware fault.
0x 0003 Ethernet normal System is good.
PODD
Network:
Ethernet PA4
(94)
Modman Input
(01)
0x 0000 Ethernet no layer 1 Indicates nothing is connected:
- Check wiring between boxes.
- Check TX box is operating.
- Check RX box is operating.
0x 0001 Ethernet no traffic Is a warning that on traffic has been seen
on the bus, but layer 1 is established so a
physical link exists.
0x 0002 Ethernet high packet
loss
There is an intermittent wiring problem or
hardware fault.
0x 0003 Ethernet normal System is good.
RF TX
Modman to
KRFU (B0)
Unknown (00) 0x 0001 TX IF Check the interconnecting RF connection
between the Modman and KRFU LRUs.
0x 0002 50 MHz Ref
RF TX KRFU
to OAE (B1)
Unknown (00) 0x 0001 TX Ka Band Check the interconnecting RF connection
between the KRFU and OAE LRUs.
RF RX (B2) Unknown (00) 0x 0001 RX cabling Check the interconnecting RF connection
between the effected LRUs.