E. TMA
Section Condition Category
4 Temperature and altitude F2
5 Temperature variation A
6 Humidity B
7 Operational shocks and crash safety E
8 Vibration CAT R, CURVE E
CAT R, CURVE E1
9 Explosive atmosphere E and H
10 Waterproofness Y and W
11 Fluid susceptibility F (de-icing fluids)
NOTE: Ethylene Glycol.
12 Sand and dust D
13 Fungus resistance F
14 Salt fog S
15 Magnetic effect A
16 Power input X - not required
17 Voltage spike A
NOTE: Do DO-160G/17.0 on TMA with the KANDU attached as the UUT.
The length of test cable between TMA and KANDU shall be 40 ft (12 m).
18 Audio frequency conducted susceptibility R
NOTE:
A. Frequency range from 324 Hz to 650 Hz.
B. Do DO-160G/18.0 on TMA with the KANDU attached as the UUT.
The length of test cable between TMA and KANDU shall be 40 ft (12 m).
19 Induced signal susceptibility ZC
20 Radio frequency susceptibility YQ (custom)
NOTE: Q (custom) only - SW/CW (un-modulated) signal Operational:
200V/m for 100 MHz to 12 GHz
0.1 V/m 12 GHz to 16.6 GHz
No damage:
200V/m for 12 GHz to 16.6 GHz
0.1 V/m for 16.6 GHz to 18 GHz
21 Emissions of RF energy H