User Manual Part 3

Page A-9
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
22 Lightning induced transient susceptibility A3K3L3 modified
NOTE: Pin Injection waveform 5A level 2. Single stroke WF 4, level 3 (extended to 300V/1000A),
Multi-stroke WF4 level 3 (extended to 120V/400A 1st stroke, 75V/150A subsequent strokes),
Extend WF5A level 3 (extended 120V/400A 1st stroke, 75V/150A subsequent strokes).
23 Lightning direct effects X - not required
24 Icing B
25 Electrostatic discharge A
26 Fire, flammability C - covers 4 CFR 25.853
Section Condition Category