21 Emissions of RF energy H
NOTE:
Extension of conducted emissions limits to 200 MHz at 20 dBμA and power line limits from
30MHz to 152MHz at 20 dBμA.
All conducted emissions limits, including interconnecting bundles limits, are set in accordance
with Category H power line limit levels.
Radiated emissions to start at 40 dBμV/m at 2 MHz to 35 dBμV/m at 25 MHz, and at 35 dBμV/m
at 25 MHz to 44.6 dBμV/m at 100 MHz
22 Lightning induced transient susceptibility A3K3L3
NOTE: Pin Injection waveform 5A level 125V/125A and 400V/4A. Single stroke WF 4, level 3
(extended to 300V/1000A), Multi-stroke WF4 level 3 (extended to 120V/400A 1st stroke,
60V/120A subsequent strokes).
23 Lightning direct effects X - not required
24 Icing B
25 Electrostatic discharge A
26 Fire, flammability C - covers 14 CFR 25.853
Section Condition Category