User Manual Part 3

Page D-8
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
C. APM (Cont) Electrical wiring
- APM to
Modman
Connect the APM to the Modman with
two twisted shielded 24 AWG pairs with
Teflon insulation or aerospace grade
shielded CAT5/CAT5e cable, maximum
length 9.8 feet (3 m).
D. KANDU Physical Examine for physical damage.
Environmental conditions, refer to
Figure 2-26
Mounting
Install location of KANDU is airframe
specific.
The KANDU is installed inside a
pressurized location, the KANDU to
KRFU and KANDU to FMA interconnect
are routed through a Bulkhead Interface
connectors.
Electrical
Wiring
KANDU-FMA
Refer to JetWave™ System LRU
Installation, KANDU on page 2-6.
E. KRFU Physical Examine for physical damage.
Environmental conditions, refer to
Figure 2-27, Figure 2-28, or Figure 2-29
depending on configuration used.
Install the thermal pad in accordance with
KRFU Thermal Pad Kit on page 2-9.
The KRFU is installed with the FMA, refer
to FMA Installation Procedure on
page 2-29.
The KRFU feet are configured differently
depending on the part number ordered.
Make sure feet are in the correct
configuration for the aircraft application.
Waveguide Make sure the waveguide is connected
before powering the KRFU.
Waveguide -
KRFU to FMA
Connection must be WR28 for TX and
coaxial cable for RX.
The TX interconnect path loss
Section Parameter Item NA Value