User Manual Part 3

Page 3-21
16 Sep 2015
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Modman Reset Input
(1) Activate the Modman Reset by toggling Modman reset switch on the JetWave™ AES control
panel.
(2) Monitor the Modman ”power” and “status” LEDs flash continuously.
(3) Toggle the Modman Reset switch on the Satcom test panel to the open/non-grounded
position.
(4) Monitor the “status” LED on the front of the Modman, progresses from red color to steady
state green as seen during initial power-on.
(5) Check for the Aircraft Tail number page and make sure that the aircraft tail number page is
updated with the aircraft Tail number.
Navigate to the AES Summary and Link Status page and scroll down to see the ARINC 791
Discrete input and output state of the JetWave™ system. Refer to Figure 3-12.
For illustration, the figure that follows shows the AES discrete signal state. Use the wired aircraft
interfaces to toggle and see if the applicable discrete are asserted or de-asserted.
Figure 3-12. Discrete I/O State
C. ARINC 429 Input Interface Testing
For the operation of JetWave
TM
system, the aircraft must have a functional IRS providing ARINC
429 labels to KANDU. Functional IRS is interfaced with the KANDU through Receive only ARINC