User's Manual Part 1

Table Of Contents
Page 2-3
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
B. JetWave™ System LRU Leading Particulars
(1) Refer to Table 2-4 for the Modman leading particulars.
(2) Refer to Table 2-5 for the APM leading particulars.
(3) Refer to Table 2-6 for the KANDU leading particulars.
(4) Refer to Table 2-7 for the KRFU leading particulars.
(5) Refer to Table 2-8 for the TMA leading particulars.
(6) Refer to Table 2-9 for the FMA leading particulars.
(7) Refer to Table 2-10 for the B757 FMA radome particulars..
Table 2-3. Non A791 Style Radome Package Variant
Airc
raft Non
A791 Style Radome Package Variant
A319/A320/A321 90400016-01
A330/A340 90400016-02
A350 90400016-03
A380 90400016-04
B737/B757 90400016-05
B747 90400016-06
B777 90400016-08
B787 90400016-09
B767 90400016-10
Table 2-4. Modman Leading Particulars
Characteristic Specification
Length 15.32 inches (389.1 mm) maximum
Width
5.02 inche
s (127.5 mm) maximum
Height 7.88 inches (200.2 mm) maximum
Weight 14.0 pounds (6.35 kg) maximum
Operating voltage 115 VAC, 400 Hz
Power consumption 60 watts maximum
NOTE: Honeywell recommends that wiring and cooling is
designed for 100 watts in order to allow for seamless upgrades
to the Modman with enhanced capability at a later date.
Power dissipation 59 watts maximum
Cooling 48.5 lb/hr (22 kg/hr) at 104°F (40°C)
Operating temperature -40°F (-40°C) to 158°F (70°C)
Draft as of 31 May 2017