ModMan Reset ModMan J1-MP10C This discrete can be
used to reset the
ModMan (and, in turn
the entire AES)
Ground = Mod-
Man/AES reset
Open = Mod-
Man/AES normal
operation
Signal type: Input
Optional
Data Link Available ModMan J1-MP13F The Data Link Available
ARINC 791 IO discrete
output shall be grounded
when user service is
available (data
connections are
available for use), and
open when user service
is not available.
Signal type: Output
(closure to ground)
Optional
System Available ModMan J1-MP13E The System Available
ARINC 791 IO discrete
output shall be open
when the AES system is
in critical fault mode, and
grounded at all other
times (including power
on sequence)
Signal type: Output
(closure to ground)
Optional
Front Panel Enable
Mode
ModMan J1-B Pin 10F The front panel enable
mode discrete enables
the Modman front panel
connectors when
asserted.
Ground = Enable
Front Panel
Connector
Open = Disable
Front Panel
Connector.
Signal type: Input
Mandatory
Table 4-3. Discretes Table (Continued)
Discrete I/O Pin Description Mandatory / Optional