0x 0006 LRU PRI-SEC image mismatch - Reboot the LRU to load valid
primary image and check if fault
goes away.
- If not, reloading of software is
required to load a fresh image.
0x 0007 Data load Info events - Recording what
happened in the LRU
0x 0008 Data loader connect
0x 0009 Data loader disconnect
0x 000A Operating image list
0x 000B Secondary image corruption warning A reloading of software is required
to load a fresh image.
0x 0080 No valid alignment data Reload the configuration data with
the A615A data loading process.
Software runtime
(FE)
0x 0000 Heartbeat failure No Action required, software faults
and events are dealt with by
criticality in the following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred, the system will continue
normal operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0001 GENERAL Module failure
0x 0002 RSSI Failure
0x 0003 OPEN Amip failure
0x 0004 Pointing failure
0x 0006 Application Controller Database Invalid
0x 0007 Application not Present
0x 0008 Application Unable to Start
0x 0009 Application fails during monitoring
0x 000A Base Application Construction failure
0x 000B Base Application Initialization failure
0x 000C Base Application runtime warning
0x 000D Base Application runtime failure
0x 000E F&E DB fails to open
0x 000F F&E DB invalid
0x 0010 F&E ODB fails to open
0x 0011 F&E code unknown
0x 0012 F&E Networking error
0x 0013 F&E Bite Action Error
0x 0014 F&E Persistent DB fails to open
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017