User's Manual Part 6

Page 7-48
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KANDU
(06)
Software runtime
(FE)
0x 0015 F&E Persistent Store Write error No Action required, software faults
and events are dealt with by
criticality in the following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred, the system will continue
normal operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0016 F&E Bite Action Inhibit
0x 0017 Data Loader TFTP timeout
0x 0018 Data Loader out of memory
0x 0019 Data Loader Load Installer missing
0x 001A Data Loader Load installer memory
error
0x 001B Data Loader primary image corruption
0x 001C Data Loader incompatible image
0x 001D ICC unable to load driver
0x 001E Inter LRU serial comms overrun
0x 001F Tunnel interface errors
0x 0020 FILE SYSTEM FULL
0x 0021 Aircraft Info Server – CVT register
access failed
0x 0022 Aircraft Info Server –no messages from
DSP
0x 0023 Aircraft Info Server ICC open failure
0x 0024 Antenna Control Status - Configured
for no OAE
0x 0025 Antenna Control Status – Configured
for manual pointing
0x 0026 Antenna Control Status ICC open
failure
0x 0027 Configuration Data Manager ICC open
failure
0x 0028 Configuration Data Manager Database
not consistent
0x 0029 Configuration Data Manager OAE
Alignment store no response
0x 002A Configuration Data Manager OAE
Alignment store not consistent
0x 002B DSP Manager Data Manager ICC open
failure
0x 002C DSP Manager Task’s stopped
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017