23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KANDU
(06)
Software runtime
(FE)
0x 0049 IP Tunnel driver – fails to initialize No Action required, software faults
and
events
are dealt with by criticality in the
following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset
in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred,
the system will continue normal
operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0050 Tunnel Driver ICC open failure
0x 004A Unable to configure routing to TMA
0x 004B KANDU /TMA network configuration
conflict
0x 0050 KANDU Post Time Out
0x 0800 MES client registration fails
0x 0801 MES client publish fail due to
attempted blocking send
0x 0802 MES server unable to open well known
socket0
0x 0803 MES server network resource limitation
- socket
0x 0804 MES server network resource limitation
– buffer
0x 0805 MES server message ID map
corruption
0x 0806 MES Client receives non-subscribed
message
0x 0807 MES proxy database Invalid0x
0x 0808 MES Proxy cannot remotely subscribe
0x 0809 EUI data missing
0x 080A ACM General Error0x
0x 080B APM Client – Data not available
0x 080C APM Client – Data validated
0x 080D APM Client – Data not validated
0x 080E RSSI Manager unable to open well
known socket
Temperature
(FF)
0x 0001 ASC main temperature sensor - If is a warning, it is for info only.
- If it is critical the LRU will shut
down
functionally: suggest the LRU is not
correctly installed or a subassembly
in the LRU may be generating too
much heat.
0x 0002 KANDU PSU remote temperature
Table 7-6. L3 Codes (Continued)