User's Manual Part 6

Page 7-69
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
IRU
Input Bus
(70)
Flight phase (41) 0x 0002 SSM FT Expected label is in functional test:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work. If the fault is a warning,
the label is expected but not there,
system will continue to operate.
0x 0003 SSM NCD Expected label is in no computed
data:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work. If the fault is a warning,
the label is expected but not there,
system will continue to operate.
0x 0004 SSM FW Expected label is in failure warning:
If a fault is critical, the system will
not work. If the fault is a warning,
the label is expected but not there,
system will continue to operate.
0x 0005 SSM NO Normal operation, system is good.
MLG ground
condition (42)
0x 0001 Missing Expected label is not there:
- Make sure that the system
configuration expects the correct
label.
- Check aircraft system is supplying
the correct label on the bus.
If fault is critical, the system will not
work. If fault is a warning, the label
is expected but not there, the
system will continue to operate.
0x 0002 SSM FT Expected label is in functional test:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work. If the fault is a warning,
the label is expected but not there,
system will continue to operate.
0x 0003 SSM NCD Expected label is in no computed
data:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work. If the fault is a warning,
the label is expected but not there,
system will continue to operate.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017