User's Manual Part 6

Page 7-70
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
IRU Input
Bus (70)
MLG ground
condition (42)
0x 0004 SSM FW Expected label is in failure warning:
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
0x 0005 SSM NO Normal operation, system is good.
Ground speed
(43)
0x 0001 Missing
0x 0002 SSM FT Expected label is in functional test:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
0x 0003 SSM NCD Expected label is in no computed
data: This is expected, but is
recorded as a debug aid.
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
0x 0004 SSM FW Expected label is in failure warning:
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
0x 0005 SSM NO Normal operation, system is good.
Body Pitch
Acceleration
(50)
0x 0001 Missing
0x 0002 SSM FT Expected label is in functional test:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action