stabilization (21)
0x 0001 Missing Expected label is not there:
- Make sure that the system
configuration expects the correct
label.
- Check aircraft system is supplying
the correct label on the bus.
If fault is critical, the system will not
work.
If fault is a warning, the label is
expected but not there, the system
will continue to operate.
0x 0002 SSM FT Expected label is in functional test:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
0x 0003 SSM NCD Expected label is in no computed
data:
This is expected, but is recorded as
a debug aid.
If a fault is critical, the system will
not work.
If the fault is a warning, the label is
expected but not there, system will
continue to operate.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action