User's Manual Part 6

Page 7-94
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
PIESD
Network:
Ethernet
EN6 (8A)
Modman Input
(01)
0x 0000 Ethernet no layer 1 Indicates nothing is connected:
- Check wiring between boxes.
- Check TX box is operating.
- Check RX box is operating.
0x 0001 Ethernet no traffic Is a warning that no traffic has been
seen on the bus, but layer 1 is
established so a physical link exists.
0x 0002 Ethernet high packet loss There is an intermittent wiring
problem or hardware fault.
0x 0003 Ethernet normal System is good.
PIESD
Network:
Ethernet
EN7 (8B)
Modman Input
(01)
0x 0000 Ethernet no layer 1 Indicates nothing is connected:
- Check wiring between boxes.
- Check TX box is operating.
- Check RX box is operating.
0x 0001 Ethernet no traffic Is a warning that no traffic has been
seen on the bus, but layer 1 is
established so a physical link exists.
0x 0002 Ethernet high packet loss There is an intermittent wiring
problem or hardware fault.
0x 0003 Ethernet normal System is good.
PIESD
Network:
Ethernet
EN8 (8C)
Modman Input
(01)
0x 0000 Ethernet no layer 1 Indicates nothing is connected:
- Check wiring between boxes.
- Check TX box is operating.
- Check RX box is operating.
0x 0001 Ethernet no traffic Is a warning that no traffic has been
seen on the bus, but layer 1 is
established so a physical link exists.
0x 0002 Ethernet high packet loss There is an intermittent wiring
problem or hardware fault.
0x 0003 Ethernet normal System is good.
PODD
Network:
Ethernet
PG1 (90)
Modman Input
(01)
0x 0000 Ethernet no layer 1 Indicates nothing is connected:
- Check wiring between boxes.
- Check TX box is operating.
- Check RX box is operating.
0x 0001 Ethernet no traffic Is a warning that no traffic has been
seen on the bus, but layer 1 is
established so a physical link exists.
0x 0002 Ethernet high packet loss There is an intermittent wiring
problem or hardware fault.
0x 0003 Ethernet normal System is good.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017