User's Manual Part 6

Page 7-99
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services IP Modman
User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1 AES services IP KANDU
User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/AV1/2/3/AG1
AES services IP OAE
User Port AES services IP subnet
User Port PA1/2/3/4/PG1/EN5/6/7/8/EG1/A
V1/2/3/AG1 traffic services
User Port IP filter 1 thru 150.
Once the items have been loaded into the APM the Modman reads the APM once at power-on and
pa
sses
the appropriate data to the relevant LRU or uses the information locally.
(1) If the Ethernet port is not active, do as
follows:
(a) Check the APM settings, as follows:
1 Make sure that the port is enabled.
2
Check system errors.
3
Check for system reporting No layer 1 or No traffic faults.
(b) Is the device connecting to it operating correctly? If so, check the wiring.
(2) It there is poor performance on one port only, do as follows:
(a) Check for port reporting high packet loss. If so, chec
k wiring and verify that there is
traffic.
(3) If not supplying access to the correct
services, do as follows:
(a) Make sure the APM is configured for the correct services.
(b) Make sure the APM is configured to access the correct VLANs.
Check with the service provider to make sure that the VLANs have been correctly configured for
the terminal.
Draft as of 31 May 2017