20 Radio frequency susceptibility RR (custom)
NOTE:
Radiated: Additional subjections
SW: 0.4 to 8 GHz: 28 V/m (1 kHz square mod with greater than 90% depth switched on and off
at 1 Hz rate and 50% duty cycle).
PM: 0.4 to 8 GHz: 150 V/m (Pulse repetition frequency of 1 kHz and a duty cycle of 1%, switched
on and off at 1 Hz rate and 50% duty cycle). Pulse width is 10 µsec (1% of 1 kHz).
PM: 0.3 to 6 GHz: 20 V/m, (Pulse repetition frequency of 200 Hz and a duty cycle of 12.5%).
Pulse width is 625 μsec (12.5% of 200Hz).
21 Emissions of RF energy M
22 Lightning induced transient susceptibility A2K2L3
NOTE: Modified to extend single stroke to waveform 3 level 3 and multi-stroke to waveform 4
level 2.
23 Lightning direct effects X - not required
24 Icing X - not required
25 Electrostatic discharge A
26 Fire, flammability C - covers 14 CFR 25.853