User's Manual Part 6

Page A-6
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
D. KRFU
Section Condition Category
4 Temp
erature and altitude D2
NOTE: Altitude test extended to 51,000 feet (15,544.8 m). Overpressure 28.9 PSI (199 kPa),
Decompression 6,000 to 55,000 (1,828.8 to 16,764.0 m).
5 Temperature variation A
6 Humidity B
NOTE: At least six spot checks required.
7 Operational shocks and crash safety E and B
8 Vibration CAT R, CURVE E
CAT R, CURVE E1
NOTE: The sinusoidal sweep rate not to exceed 0.5 octaves/minute.
9 Explosive atmosphere E
10 Waterproofness Y and R
11 Fluid susceptibility F
NOTE: Ethylene Glycol, Propylene Glycol, AEA Type 1, AEA Type 2.
12 Sand and dust D
13 Fungus resistance F
14 Salt fog S
15 Magnetic effect Z
16 Power input A (WF) HZPI
NOTE: Extended low frequency operation to 320 Hz.
NOTE: Power Factor – leading greater than 0.98.
17 Voltage spike A (modified to 1,000 volts)
18 Audio frequency conducted susceptibility K (WF)
NOTE: RMS amplitude of the audio signal extended to not less than 10% of the maximum normal
AC input voltage and with a power source frequency of 320 Hz in addition to 360 Hz and 800 Hz.
19 Induced signal susceptibility CW
NOTE: Extended low frequency operation to 320 Hz.
NOTE: Section 19.3.1 performed with 50 A at a distance of 0.4 inch (10 mm).
20 Radio frequency susceptibility MY
NOTEL:
- 0.4 to 8 GHz: 150 V/m (Pulse repetition frequency of 1 kHz and a duty cycle of 1%, switched
on and off at a 1 Hz rate and 50% duty cycle). Pulse width is 10 μsec (1% of 1 kHz).
- 0.3 to 6 GHz: 20 V/m, (Pulse repetition frequency of 200 Hz and a duty cycle of 12.5%). Pulse
width is 625 μsec (12.5% of 200 Hz).
Draft as of 31 May 2017