User's Manual Part 6

Page A-8
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
E. TMA
Section Condition Category
4 Temp
erature and altitude F2
5 Temperature variation A
6 Humidity B
7 Operational shocks and crash safety E
8 Vibration CAT R, CURVE E
CAT R, CURVE E1
9 Explosive atmosphere E and H
10 Waterproofness Y and W
11 Fluid susceptibility F (de-icing fluids)
NOTE: Ethylene Glycol.
12 Sand and dust D
13 Fungus resistance F
14 Salt fog S
15 Magnetic effect A
16 Power input X - not required
17 Voltage spike A
NOTE: Do DO-160G/17.0 on TMA with the KANDU attached as the UUT.
The length of test cable between TMA and KANDU shall be 40 ft (12 m).
18 Audio frequency conducted susceptibility R
NOTE:
A. Frequency range from 324 Hz to 650 Hz.
B. Do DO-160G/18.0 on TMA with the KANDU attached as the UUT.
The length of test cable between TMA and KANDU shall be 40 ft (12 m).
19 Induced signal susceptibility ZC
20 Radio frequency susceptibility YQ (custom)
NOTE: Q (custom) only - SW/CW (un-modulated) signal Operational:
200V/m for 100 MHz to 12 GHz
0.1 V/m 12 GHz to 16.6 GHz
No damage:
200V/m for 12 GHz to 16.6 GHz
0.1 V/m for 16.6 GHz to 18 GHz
21 Emissions of RF energy H
22 Lightning induced transient susceptibility A3K3L3 modified
NOTE: Pin Injection waveform 5A level 2. Single stroke WF 4, level 3 (extended to 300V/1000A),
Multi-stroke WF4 level 3 (extended to 120V/400A 1st stroke, 75V/150A subsequent strokes),
Extend WF5A level 3 (extended 120V/400A 1st stroke, 75V/150A subsequent strokes).
Draft as of 31 May 2017