F. FMA
Section Condition Category
4 Temp
erature and altitude F2
NOTE: Extended operating high to 194
˚F (90˚C).
5 Temperature variation A
6 Humidity B
NOTE: At least six spot checks are required.
7 Operational shocks and crash safety B and E
8 Vibration CAT S, CURVE C
CAT R, CURVE C1
NOTE: The sinusoidal sweep rate not to exceed 0.5 octaves/minute
9 Explosive atmosphere E
10 Waterproofness Y and W
11 Fluid susceptibility - De-ice fluids only F
12 Sand and dust D
13 Fungus resistance F
14 Salt fog S
15 Magnetic effect B
16 Power input X - not required
17 Voltage spike X - not required
18 Audio frequency conducted susceptibility X - not required
19 Induced signal susceptibility ZC
20 Radio frequency susceptibility YQ
NOTE: Q (custom) only - SW/CW (un-modulated) signal Operational:
200V/m for 100 MHz to 12 GHz
0.1 V/m 12 GHz to 16.6 GHz
No damage:
200V/m for 12 GHz to 16.6 GHz
0.1 V/m for 16.6 GHz to 18 GHz
21 Emissions of RF energy H
NOTE:
Extension of conducted emissions limits to 200 MHz at 20 dBμA and power line limits from
30MHz to 152MHz at 20 dBμA.
All conducted emissions limits, including interconnecting bundles limits, are set in accordance
with Category H power line limit levels.
Radiated emissions to start at 40 dBμV/m at 2 MHz to 35 dBμV/m at 25 MHz, and at 35 dBμV/m
at 25 MHz to 44.6 dBμV/m at 100 MHz