User's Manual Part 6

Page C-7
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
A. Modman (Cont) Clearance Minimum 1 inch (25.4 mm) from top
surface and 0.5 inch (12.7 mm) from all
other surfaces
Electrical
connector
ARINC 600 mating connector and pins,
refer to Table 4-1. ARINC 600
Connectors
ARINC 600 polarized pins
Electrical
bonding
Bonding, refer to page 4-3
Electrical
wiring
Electrically wire and interconnect in
accordance with Figure 4-21 or
Figure 4-22 and Figure 4-35 thru
Figure 4-37, depending on the
configuration being used.
Electrical RF
coaxial
Equalizer in the TX path
TX path loss, refer to Table 4-2. Modman
Cable Loss Values
Attenuator in the RX path
RX path loss, refer to Table 4-2.
Modman Cable Loss Values
NOTE: Input signal
range: -79 to -5 dBm.
Output signal range -30
to +5 dBm. Incross talk
requirement: -25 dBc.
Output cross talk
requirement: -40
dBc.APM
Physical Examine for physical damage.
Environmental conditions, refer to
Figure 4-21 and Figure 4-22.
Mounting Can be installed in any orientation. Refer
Figure 4-21 and Figure 4-22.
Use 0.164-32 UNC-2A corrosion
resistant mounting fasteners.
Do not exceed 25 in-lb (2.8 Nm) when
you torque the screws.
Electrical
bonding
Electrically bond in accordance with
page 4-4.
Electrical
wiring
Electrically wire and interconnect in
accordance with Figure 4-24 and
Figure 4-35 thru Figure 4-37, depending
on the configuration being used.
Section Parameter Item NA Value
Draft as of 31 May 2017