C. Non-A791 Based OAE-FMA with the LAIM Checklist
Section Parameter Item NA Valu
e
A. Maintenance Panel Applicability If the system is not wired to another
aircraft system, an installer provided
maintenance panel is required.
Discrete
output
connections
System available (Modman MP13E)
connected to a lamp
Data link available (Modman MP13F)
connected to a lamp
Discrete input
connections
Local data load enable (Modman
MP10B) connected to a normally open
switch
Ground transmit enable (Modman
MP11D) connected to a normally open
switch
Public service disable (Modman
MP11E) connected to a normally open
switch
Modman reset (Modman MP10C)
connected to a normally open switch
Tx mute (KANDU J1D) connected to a
normally open switch
Ethernet port
connections
AV1 (Modman TP BB1 thru 4)
connected to a RJ45 Ethernet connector
Additional
electrical
wiring
Electrically wire and interconnect in
accordance with Figure 4-35 thru
Figure 4-37, depending on the
configuration being used.
A. Modman Physical Examine for physical damage.
Environmental conditions, refer to
Figure 4-21 or Figure 4-22.
Mounting tray Install applicable 4-MCU tray, supplied
by customer.
Clearance Minimum 1 inch (25.4 mm) from top
surface and 0.5 inch (12.7 mm) from all
other surfaces.
Electrical
connector
ARINC 600 mating connector and pins,
refer to Table 4-1. ARINC 600
Connectors
ARINC 600 polarized pins