SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
has completed successfully. Once all LRUs are updated, de-assert the data load
discrete to reset the system (100%)”.
(o) If loading additional software, again execute the steps above starting with Step (h).
(p) Once all software upgrades are completed, toggle the
‘Data Load Enable’ discrete to the
‘Disabled’ state. This will cause a system reboot.
(q) On the data load PC, using a web browser (preferably Firefox or Chrome), point to IP
address ‘172.29.55.1’ in the browser to open
the AES GUI as shown below. Log in and
view the system status info at the top of the GUI window. At the GUI login, the username
is "User" and there is no password.
(r) Each LRU can be checked by selecting the respective LRU na
me under “Version &
Manufacturing Information”.
(s) Each LRU page will have the hardware part and serial numbers, as
well as the software
part numbering information and CRCs for each sub part. This information should match
Draft as of 31 May 2017