SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
C. System Data Load Failure
(1) Make sure that the system is configured for ground operation.
(2) Make sure that the local data load enable switch is closed.
(3) Make sure that the ARINC 615A data loader is connected to the correct port:
NOTE: Port AV1 is by default the Modman Maintenance Port, but this may have been
modified by the APM configuration loaded.
D. System Reset
The JetWave™ system can be reset with any of the methods that follow:
• GUI
Through the SNMP
By grounding the Modman Reset Pin (MP10C).
NOTE:
The maintenance technician can attempt to cycle power to the Modman in case the system fails
to respond to the reset. If the problem persists, the respective AES sub assembly needs to be
replaced. The operator's JetWave Customer Support can be contacted for further support.
E. Electrical and Mechanical Inspection and Check
Periodic inspections of the mechanical and electrical interfaces of the JetWave™
AES OAE
assembly and LRUs to the aircraft should be completed as defined by the governing airworthiness
body (such as Transport Canada, the FAA, or the JAA) Instructions for Continued Airworthiness for
the installation.
For the general guidelines, refer to Visual Inspection and Check and Scheduled Maintenance and
Inspections sections.
F. Visual Inspection and Check
Do the procedures that follow to examine the JetWave™
AES OAE assembly and LRUs after
installation of the unit onto the aircraft. Follow all approved safety standards and practices during
the inspection.
WARNING: FAILURE TO DISCONNECT CIRCUIT BREAKERS CAN LEAD TO INJURY TO THE
OPERAT
OR AND DAMAGE TO THE EQUIPMENT.
(1) Disconnect all circuit breakers to the JetWave™ AES OAE assembly, LRUs and associated
sys
tems.
(2) Visually examine the FMA or TMA radome for any damage or defects. Please refer to the
radome sup
plier’s Structural Repair Manual (SRM) for the specific radome inspection and
damage repair instructions.
NOTE: Saint Gobain SRM-100 is applicable to all radomes. FMA radome, PN
SCD-90401395-01, is covered specifically by Saint Gobain SRM-5249 structural
repair manual.