User's Manual Part 6

Page 7-12
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
(2) LRU Codes
BITE event information is encoded by the LRUs in three value
s. The values are named L1
thru L3:
L1 denotes the LRU or interface (generated by an LRU on its behalf) which
is ge
nerating the event
L2 denotes the Shop Replaceable Module within an LRU for a event relating
to an LR
U, or for interfaces it denotes a particular part of the interface which
is generating the event.
L3 further defines the unique event that occurred.
Each fault or event also has an additional text field which can carry additional information
he
lpful to under
stand the fault or event that happened.
The combination of L1 thru L3 alone uniquely identifies a BITE event in the system.
(3) L1 Codes
(a) The event L1 code uses two hexadecimal digits to ide
ntify a LRU or an interface within
an AES LRU, coded as follows:
Table 7-1. L1 Codes
Group L1 Code
L1 Description
System 0x 00 System
The L1 code of 00 shall be used if the LRU is
unknown or if the error is applicable to a system level,
such as an invalid or unknown system configuration
error, or a system event not specific to an LRU.
AES 0x 01 Modman
0x 02 KRFU
0x 03 TMA
0x 04 FMA
0x 05 APM
0x 06 KANDU
Draft as of 31 May 2017