System
(00)
AES menu
access level (02)
0x 0023 Log clearance AES usage historical log - Info events - Recording what
happened in the LRU.
- If it is a warning, it is info only.
Configuration
(03)
0x 0000 Tail number missing Use the AES Menu interface at
maintenance level to enter the valid
tail number of the aircraft
0x 0001 Configuration file missing - First fit: Data load the
configuration data to the Modman
LRU with the 615A data loading
process.
- After operational: Replace the
APM LRU (presume it is defective
since the APM should not forget an
APM file), do the first fit operation
again.
0x 0002 Inter LRU SW incompatibility Verify versions of SW with the GUI
or AES menu tool on all LRUs and
replace with correctly configured set
of SW.
0x 0003 Geographical map missing NO ACTION – this will be updated
when the system is in operation.
0x 0004 Configuration file in APM missing - First fit: Data load the
configuration data to the Modman
LRU with the 615A data loading
process.
- After operational: Replace the
APM LRU (presume it is defective
since the APM should not forget an
APM file), do the first fit operation
again.
AES SFTP (04) 0x 0000 Maintenance - Info events - Recording what
happened in the LRU.
- If it is a warning, it is info only.
0x 0001 Factory
0x 0002 Engineering
SNMP
Engineering (05)
0x 0000 Maintenance
0x 0001 Factory
0x 0002 Engineering
0x 0021 Log clearance AES operational
historical log
0x 0022 Log clearance AES fault historical log
0x 0023 Log clearance AES usage historical log
SNMP ARINC
791 (06)
0x 0000 Maintenance
0x 0001 Factory
0x 0002 Engineering
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017