User's Manual Part 6

Page 7-22
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
System
(00)
Regulatory Log
(07)
0x 0000 Regulatory log upload failure NO ACTION –System will continue
to try and upload the file as directed
by the regulatory log requirements
on frequency of upload attempts.
0x 0001 Reg log full NO ACTION –System will continue
to try and upload the file as directed
by the regulatory log requirements
on frequency of upload attempts.
User data traffic will be disabled
until the log is successfully
uploaded.
Information
Events (08)
0x 0000 User service enabled NO ACTION: - This is AES
Information Event
0x 0001 User service disabled NO ACTION: - Will recover next
time
0x 0002 Geographic map stored NO ACTION: - This is information
event
0x 0003 Geographic map download failed NO ACTION: - Will recover next
system power cycle.
0x 0004 Aircraft on ground NO ACTION: - This is Information
Event
0x 0005 Aircraft in air NO ACTION: - This is Information
Event
0x 0006 AES in network NO ACTION: - This is Information
Event
0x 0007 AES out of network NO ACTION: - This is Information
Event
0x 0008 AES network operating parameters NO ACTION: - This is Information
Event
Software
Runtime (FE)
0x 0000 No Comms with OAE – KANDU OK No action required, software faults
and events are dealt with by
criticality in the following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred, the system will continue
normal operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0001 System POST Event
0x 0002 LRU Comms Established
0x 0003 LRU Comms Not Established
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017