User's Manual Part 6

Page 7-25
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Modman
(01)
Controller
/router (02)
0x 0023 RSSI control in/out IO Hardware faults and events:
- Replace the Modman.
0x 0024 Unique ID chip
0x 0030 5V ISO good - power fail
0x 0031 12V ISO good - power fail
0x 0032 1V2 AR power good - power fail
0x 0033 APM power good - power fail
0x 0034 RSSI VDD power good - power fail
0X0035 RSSI +1V3 power good - power fail
Power supply
unit (03)
0x 0001 PSU input power fail
0x 0002 PSU good power fail
Backplane (04) 0x 0001 ACM 18V power good
Operational
information (FA)
0x 0000 Mode Transition Info events - Recording what
happened in the LRU.
0x 0001 Parameter
0x 0002 Operational event
0x 0004 Connect event
0x 0005 Disconnect event
0x 0006 User Bytes passed
0x 000A Standard electronic information
0x 000B Honeywell electronic information
0x 000C Subassembly information
IP security (FB) 0x 0000 Critical IP events NO ACTION:- This is information
event.
0x 0001 Warning IP security events NO ACTION:- This is information
event.
0x 0020 Configuration fault Use correct network configuration
Reset (FC) 0x 0000 Power Cycle Info events - Recording what
happened in the LRU.
0x 0001 Watchdog
0x 0002 Software Command
0x 0003 Reset Pin Info events - Recording what
happened in the LRU.
0x 0004 SW exception
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017