User's Manual Part 6

Page 7-26
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Modman
(01)
Software
configuration
(FD)
0x 0001 HW SW compatibility Reload compatible software with
the A615A data loading process.
0x 0002 LRU SW compatibility
0x 0003 Configuration parameter missing Reload the configuration data with
the A615A data loading process.
0x 0004 Primary image corruption warning - Reboot the LRU after 10 minutes
of power application.
- If not, then reloading of software is
required to load a fresh image.
0x 0005 No valid image Reload compatible software with
the A615A data loading process.
0x 0006 LRU PRI-SEC image mismatch - Reboot the LRU after 10 minutes
of power application.
- If not, then a reloading of software
is required to load a fresh image.
0x 0007 Data load Info events - Recording what
happened in the LRU.
0x 0008 Data loader connect
0x 0009 Data loader disconnect
0x 000A Operating image list
0x 000B Secondary image corruption warning Perform a system reset.
0X 0040 VLAN MAPPING TO SPECIFIC
PORTS DISALLOWED
NO ACTION - It is info only. This
warning gets generated if the
mapping ordered by the ACM fails
due to the configuration data.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action