User's Manual Part 6

Page 7-27
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Modman
(01)
Software runtime
(FE)
0x 0000 Heartbeat failure No Action required, software faults
and events are dealt with by
criticality
in the following manner:
-Critical: An unrecoverable software
error has occured, the system will
reset
in order to recover.
-Warning: An unexpected but
recoverable software error has
occured,
the system will continue normal
operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0001 GENERAL module failure
0x 0006 Application Controller Database Invalid
0x 0007 Application Not Present
0x 0008 Application Unable to Start
0x 0009 Application fails during monitoring
0x 000A Base Application Construction failure
0x 000B Base Application Initialization failure
0x 000C Base Application runtime warning
0x 000D Base Application runtime failure
0x 000E F&E DB fails to open
0x 000F F&E DB invalid
0x 0010 F&E ODB fails to open
0x 0011 F&E code unknown
0x 0012 F&E Networking error
0x 0013 F&E Bite Action Error
0x 0014 F&E Persistent DB fails to open
0x 0015 F&E Persistent Store Write Error
0x 0016 F&E Bite Action Inhibit
0x 0017 Data Loader TFTP timeout
0x 0018 Data Loader out of memory
0x 0019 Data Loader Load Installer missing
0x 001A Data Loader Load Installer memory
error
0x 001B Data Loader primary image corruption
0x 001C Data Loader incompatible image
0x 001D ICC unable to load driver
Missing KANDU Information - Ground
0x 0020 Speed
0x 0021 File System Full
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017