Modman
(01)
Software runtime
(FE)
0x 0800 MES client registration fails No Action required, software faults
and events are dealt with by
criticality in the following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred, the system will continue
normal operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0801 MES client publish fail due to
attempted blocking send
0x 0802 MES server unable to open well known
socket
0x 0803 MES server network resource limitation
- socket
0x 0804 MES server network resource limitation
- buffer
0x 0805 MES server message ID map
corruption
0x 0806 MES Client receives non-subscribed
message
0x 0807 MES proxy database invalid
0x 0808 MES proxy cannot remotely subscribe
0x 0809 EUI data missing
0x 080A ACM General Error
0x 080B APM Client - Data not available
0x 080C APM Client - Data validated
0x 080D APM Client - Data not validated
0x 080E RSSI Manager unable to open well
known socket
Temperature
(FF)
0x 0001 C/R temperature sensor If it is a warning, It is info only.
- If it is critical, the LRU will shut
down functionally: The LRU is not
correctly installed or there can be a
fault in the box generating the heat.
0x 0002 PSU temperature sensor