User's Manual Part 6

Page 7-30
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KRFU
(02)
Unknown (00) 0x 0000 Mute state Info events - Recording what
happened in the LRU.
0x 0001 Primary power interruption
Power supply
(01)
0x 0002 Power supply internal fault Hardware faults and events:
- Replace the KRFU
Block up
converter (02)
0x 0001 BUC lockloss: Transmit BITE status
0x 0002 BUC lockloss: Transmit BITE status
Power amplifier
(04)
0x 0002 PA overdriven: Transmit BITE status
Monitor and
control (05)
0x 0001 Flash fault
0x 0002 RAM fault
0x 0003 Watchdog reset
BDC (2A) 0x 0001 BITE status
0x 0002 BDC lockloss: Receive It is info only. KRFU recovered from
the loss of KANDU heartbeats.
Operational
information (FA)
0x 000A Standard electronic information Info events - Recording what
happened in the LRU.
0x 000B Honeywell electronic information
Reset (FC) 0x 0001 Watchdog
0x 0002 Software command
0x 0004 SW exception
0x 0005 Power cycle or Reset pin
Software
configuration
(FD)
0x 0001 HW SW compatibility Reload compatible software with
the A615A data loading process.
0x 0004 Primary image corruption warning - Reboot the LRU to load valid
primary image and check if fault
goes away.
- If not, then reloading of software is
required to load a fresh image
0x 0006 LRU PRI-SEC image mismatch - Reboot the LRU to load valid
primary image and check if fault
goes away.
- If not, then reloading of software is
required to load a fresh image
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017