User's Manual Part 6

Page 7-31
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KRFU
(02)
Software
configuration
(FD)
0x 0007 Data load Info events - Recording what
happened in the LRU.
0x 000A Operating image list
0x 0008 Data loader connected
0x 0009 Data loader disconnected
0x 000B Secondary image corruption warning A reloading of software is required
to load a fresh image.
Software runtime
(FE)
0x 0000 KRFU - KANDU Heartbeat failure No Action required, software faults
and events are dealt with by
criticality in the following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred, the system will continue
normal operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0001 KANDU - KRFU heartbeat failure
Temperature
(FF)
0x 0001 KRFU main temperature sensor - If is a warning, it is for info only.
- If it is critical the LRU will shut
down functionally: suggest the LRU
is not correctly installed or there can
be a fault in the box generating the
heat.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017