User's Manual Part 6

Page 7-34
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
TMA (03) Software
Configuration
(FD)
0x 0001 HW SW compatibility Reload compatible software with
the A615A data loading process.
0x 0002 LRU SW compatibility
0x 0003 Configuration parameter missing Reload the configuration data with
the A615A data loading process.
0x 0004 Primary image corruption warning - Reboot the LRU to load valid
primary image and check if fault
goes away.
- If not, then reloading of software is
required to load a fresh image.
0x 0006 TMA PRI-SEC image mismatch - Reboot the LRU to load valid
primary image and check if fault
goes away.
- If not, then reloading of software is
required to load a fresh image.
0x 0007 Data load Info events:- Recording what
happened in the LRU.
0x 0008 Data loader connect
0x 0009 Data loader disconnect
0x 000A Operating image list
0x 000B Secondary image corruption warning A reloading software is required to
load a fresh image.
Software runtime
(FE)
0x 0000 Heartbeat failure No Action required, software faults
and events are dealt with by
criticality in the following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred, the system will continue
normal operation.
-Information: Recording information
related to software execution within
the LRU.
0x 0001 DSP task timeout
0x 0002 ARM-DSP communication
0x 0003 DSP task timeout
0x 0004 ARM-DSP COMMUNICATION
0x 0005 Application Controller Database Invalid
0x 0006 Application Not Present
0x 0007 Application Unable to Start
0x 0008 Application fails during monitoring
0x 0009 Application fails during monitoring
0x 000A Base Application Construction failure
0x 000B Base Application Initialization failure
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017