User's Manual Part 6

Page 7-35
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
TMA (03) Software runtime
(FE)
0x 000C Base Application runtime warning No Action required, software faults
and events are dealt with by
criticality in the following manner:
-Critical: An unrecoverable software
error has occurred, the system will
reset in order to recover.
-Warning: An unexpected but
recoverable software error has
occurred, the system will continue
normal operation.
-Information: Recording information
related to software execution within
the LRU.
0x 000D Base Application runtime failure
0x 000E F&E DB fails to open
0x 000F F&E DB invalid
0x 0010 F&E ODB fails to open
0x 0011 F&E code unknown
0x 0012 F&E Networking error
0x 0013 F&E Bite Action error
0x 0014 F&E Persistent DB fails to open
0x 0015 F&E Persistent Store Write error
0x 0016 F&E Bite Action inhibit
0x 0017 Data Loader TFTP timeout
0x 0018 Data Loader out of memory
0x 0019 Data Loader Load installer missing
0x 001A Data Loader Load installer memory
error
0x 001B Data Loader primary image corruption
0x 001C Data Loader incompatible image
0x 001D ICC unable to load driver
0x 001E Inter LRU serial comms overrun
0x 001F Tunnel interface errors
0x 0021 Alignment - fail to open file
0x 0022 Alignment - empty file
0x 0023 Alignment - corrupt file
0x 0024 Alignment - write file
0x 0025 Configuration Data Manager ICC open
failure
0x 0026 Configuration Data Manager Database
not consistent
0x 0027 TMA Controller ICC open failure
0x 002A DSP Manager Data Manager ICC open
failure
0x 002B DSP Manager Task’s stopped
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017