FMA (04) MDU (0B) 0x 0001 1.25V voltage Hardware faults and events:
- Replace the FMA
.
0x 0002 1.5V voltage
0x 0003 3.3V voltage
0x 0004 12V positive voltage
0x 0005 12V negative voltage
0x 0006 38.5V voltage
0x 0007 1.5V current
0x 0008 3.3V current
0x 0009 12V positive current
0x 000A 12V negative current
0x 000B Serial communications failure
0x 000C Azimuth motor current
0x 000D Elevation motor current
0x 000E Serial communications failure
0x 000F Azimuth axis low temperature high
current failed
0x 0010 Elevation axis low temperature high
current
R2D (0C) 0x 0001 1.5V voltage
0x 0002 3.3V voltage
0x 0003 5V digital voltage
0x 0004 5V positive voltage
0x 0005 5V negative voltage
0x 0006 12V positive voltage
0x 0007 12V negative voltage
0x 0008 1.5V current
0x 0009 3.3V current
0x 000A 12V positive current
0x 000B 12V negative current
0x 000F Serial communications failure
0x 0010 CCA initialization failed
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action