User's Manual Part 6

Page 7-40
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
FMA (04) R2D (0C) 0x 0011 Azimuth axis resolver reading error Hardware faults and events:
- Replace the FMA
0x 0012 Elevation axis resolver reading error
Operational
information (FA)
0x 0000 Mode transition Info events - Recording what
happened in the LRU
0x 0001 Parameter
0x 0002 Event
0x 000A Standard electronic information
0x 000B Honeywell electronic information
0x 000C Subassembly information
IP security (FB) 0x 0000 IP security event
Reset (FC) 0x 0000 Power cycle
0x 0001 Watchdog
0x 0002 Software command
0x 0003 RESET PIN
0x 0004 SW exception
Software
configuration
(FD)
0x 0001 HW SW Compatibility Reload compatible software with
the A615A data loading process.
0x 0002 LRU SW Compatibility
0x 0003 Configuration parameter missing Reload the configuration data with
the A615A data loading process.
0x 0004 Primary image corruption warning - Reboot the LRU to load valid
primary image and check if fault
goes away.
- If not, then reloading of software is
required to load a fresh image.
0x 0006 LRU PRI-SEC image mismatch - Reboot the LRU to load valid
primary image and check if fault
goes away.
- If not, then reloading of software is
required to load a fresh image.
0x 0007 Data load Info events- Recording what
happened in the LRU.
0x 0008 Data loader connect
0x 0009 Data loader disconnect
0x 000A Operating image list
FMA (04) Software
configuration
(FD)
0x 000B Secondary image corruption warning A reloading of software is required
to load a fresh image.
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017